Environmental Quality Laboratory Instrumentation
Organic Analysis
Agilent 1200 high-performance liquid chromatography (HPLC)
Analysis of non-volatile organic compounds in water (reverse phase chromatography)
Diode array and fluorescence detectors
Pharmaceutical and personal care products analysis
Limit of detection in μg/L range
Abraxis CAAS automated contaminant analysis system
Fully automated 96-well microplate analysis system: fluid handling, plate mixing, incubation timing, optical reading, calculating, and reporting
Uses enzyme-linked immunosorbent assay (ELISA) kits for analysis of :
- Nodularin + microcystins
- Anatoxin-a
- Cylindrospermopsin
- Saxatoxins
- Assay kits also available for
- Pesticides, herbicides
- PCBs
Agilent 6495D triple quadrupole mass spectrometer / 1290 Infinity ultrahigh performance liquid chromatograph
Analysis of 40 + PFAS compounds in various matrices in a PFAS free system minimizing background noise and contamination
PFAS MRM date base for rapid method development and quantitation
High sensitivity
Application focused tuning and workflow facilitate analysis and quantitation of personal care products and pharmaceuticals, lipids, metabolites, and pesticides in addition of PFAS
Detection levels at ng/L levels
Agilent 7890A Gas chromatograph 5975C electron impact (EI)/chemical ionization (CI) mass spectrometer
Direct liquid injection or headspace analysis with a CTC PAL autosampler system for the analysis of volatile and semi-volatile organic compounds
Frontier Laboratories Multi-shot micro furnace pyrolyzer
Characterization of natural organic matter and humic materials
Identify and quantify different types of plastic polymers
High sensitivity and low background results in 0.1 ug detection limits
Shimadzu TOC-L, TNM-L total organic carbon and total nitrogen analyzer
Analysis of total organic carbon or dissolved organic carbon in water samples with a working range from 5 μg/L to 10,000 mg/L carbon
Analysis of total nitrogen in water samples usingchemiluminescence detection
Inorganic Analysis
ThermoScientific Dionex Integrion high pressure ion chromatograph
Analysis of major cations and anions in water
Analysis of low molecular weight organic acids in water
Conductivity detector
Automated eluent generation
Agilent 8900 Triple quadrupole ICP-MS
Analysis of 30+ elements in water, soil, sediment, tissue samples
High sensitivity and low background results in ng/L detection limits
MS/MS ensures reliable results for difficult elements such as Si, P, and S
MS/MS analysis of raw earth elements
Stable isotope analysis
Particle size analysis of microplastics by single particle (sp) ICPMS
Characterization of metal nanoparticles by sp-ICPMS
Spectroscopy
Shimadzu UV-2600i UV-Vis spectrophotometer with integrating sphere
Scanning range 185-900 nm
Integrating sphere allows generation of spectrum for films, gels, creams, and metallic foils
SpectraMax iD3 Plate Reader
High-throughput absorbance, fluorescence, and luminescence assays
Horiba Aqualog
Performs A-TEEM spectroscopy, simultaneous Absorbance, Transmittance, and Fluorescence Excitation-Emission-Matrix (EEMs).
- Measuring colored dissolved organic matter (CDOM) composition
- oil-in-water analysis
- benzene, toluene, ethylbenzene and xylene (BTEX) analysis
- identifying and quantifying complex biomolecules
Microbiology
Bio-Rad CFX Opus 96 qPCR System
Real-time gene quantification and microbial community profiling with qPCR (e.g., ARGs, HABs)
ECHO Revolve 4, Hybrid Fluorescence Microscope
Fluorescence imaging of microbial and eukaryotic cells; biofilm and cell physiology studies
NanoBrook 90 Plus PALS
NanoBrook 90Plus PALS (phase analysis light scattering)
Dynamic light scattering for particles/molecules size over the range of 0.3 nm-6 μm at 90° and 15°
Phase light scattering for particle/molecular surface charge determination (zeta potential)
Sample Preparation & Additional Resources
Sample Preparation
Inorganics
- Milestone Ethos EZ Microwave Digestion System
- Environmental Express Hotblocks
Organics
- Solid Phase Extraction (SPE) of organic compounds in water samples on C18 or mixed-mode resin cartridges.
- CEM EDGE automated solvent extraction system
- Liquid-Solid extractions via traditional Soxhlet
Other Microbiology
- Bio-Rad iQ5 Real Time PCR Detection System
- Thermo Scientific Nanodrop 1000/3300
- CO2 incubators, laminar flow hood, biological safety hood
- -70° C Revco freezer
- Microscopes with phase-contrast and epifluorescence capability
Other Resources
- Two Coy anerobic glove bags
- Two constant temperature rooms (400 sq. ft. each) maintained between 10° and 30 ± 2° C